Lab ID Project # or Name Station Id Sample # or Sample ID Date Collected Time Collected Analyte or Parameter Analytical Method Results Units of Measurement Reporting Limit Date Analyzed Depth (m) Tow or Depth Composite Code Remarks NA BTWF R20 NA 9/13/1999 NA Secchi Depth NA 2.4 m NA NA NA NA NA BTWF R40 NA 9/13/1999 NA Secchi Depth NA 3.15 m NA NA NA NA NA BTWF R20 NA 9/27/1999 NA Secchi Depth NA 3.2 m NA NA NA NA NA BTWF R40 NA 9/27/1999 NA Secchi Depth NA 3.22 m NA NA NA NA NA BTWF R20 NA 10/11/1999 NA Secchi Depth NA 4 m NA NA NA NA NA BTWF R40 NA 10/11/1999 NA Secchi Depth NA 3.66 m NA NA NA NA NA BTWF R20 NA 10/25/1999 NA Secchi Depth NA 4.23 m NA NA NA NA NA BTWF R40 NA 10/25/1999 NA Secchi Depth NA 4.47 m NA NA NA NA NA BTWF R20 NA 11/15/1999 NA Secchi Depth NA 4.98 m NA NA NA NA NA BTWF R40 NA 11/15/1999 NA Secchi Depth NA 4.88 m NA NA NA NA NA BTWF R20 NA 12/20/1999 NA Secchi Depth NA 2.78 m NA NA NA NA NA BTWF R40 NA 12/20/1999 NA Secchi Depth NA 4 m NA NA NA NA FCWQL Horsetooth R41 50211 1/3/2000 na "Alkalinity, Field" SM2320B 26.2 mg/L 1.2 1/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Aluminum, Total" SM 3113 B 260 ug/L 15 1/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50213 1/3/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 1/31/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 50210 1/3/2000 na "Antimony, Total" SM3113 B *non-detect ug/L 2 2/15/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Arsenic, Total" SM3113 B *non-detect ug/L 2 3/3/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Barium, Total" SM3113 B 28.4 ug/L 20 2/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Beryllium, Total" SM3113 B *non-detect ug/L 0.5 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Cadmium, Total" SM3113 B *non-detect ug/L 0.1 2/3/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Calcium, Total" SM3111 D 7.4 mg/L 0.5 2/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50212 1/3/2000 na "Chloride, Dissolved" EPA 300.0 1.6 mg/L 1 1/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50207 1/3/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.2 ug/L 0.6 1/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Chromium, Total" SM3113 B 0.6 ug/L 0.5 1/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50211 1/3/2000 na Color SM2120 B modified 27.3 APHA units 2.5 1/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Copper, Total" SM3113 B 17.5 ug/L 3 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na Fecal Coliform SM9222 D 1 CFU/100 mL 0 1/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na Fecal Strep SM9230 C 4 CFU/100 mL 0 1/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50212 1/3/2000 na Fluoride EPA 300.0 0.16 mg/L 0.11 1/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na Heterotrophic Plate Cnt SM9215 B 40 CFU/1.0 mL 0 1/19/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Iron, Total" SM3113 B 397 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Lead, Total" SM3113 B *non-detect ug/L 1 1/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Magnesium, Total" SM3111 B 1.4 mg/L 0.2 2/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Manganese, Total" SM3113 B 37.2 ug/L 1 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Mercury, Total" EPA 245.2 *non-detect ug/L 1 1/27/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Molybdenum, Total" SM3113 B *non-detect ug/L 3 3/6/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Nickel, Total" SM3113 B *non-detect ug/L 3 2/3/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50212 1/3/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 1/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50212 1/3/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/5/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50211 1/3/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.019 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50211 1/3/2000 na "pH, Field" SM4500-H B 7.44 units NA 1/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50213 1/3/2000 na "Phosphorus, Total" SM4500-P B 0.024 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Potassium, Total" SM3111 B 1 mg/L 0.2 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Selenium, Total" SM3113 B *non-detect ug/L 2 2/23/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Silver, Total" SM3113 B *non-detect ug/L 0.5 3/23/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Sodium, Total" SM3111 B 2.3 mg/L 0.4 1/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50211 1/3/2000 na "Specific Conductance, Laboratory" SM2510 B 69.1 umhos/cm 10 1/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50212 1/3/2000 na "Sulfate, Dissolved" EPA 300.0 *non-detect mg/L 5 1/5/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 1/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Thallium, Total" EPA 200.9 *non-detect ug/L 2 2/15/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na Total Coliform SM9223 B 2 CFU/100 mL 0 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50208 1/3/2000 na Total Coliform SM9222 B 1 CFU/100 mL 0 2/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50213 1/3/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.2 mg/L 0.1 1/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50209 1/3/2000 na Total Organic Carbon SM5310B 3.5 mg/L 0.83 1/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50211 1/3/2000 na Turbidity SM2130 B 3.2 NTU 0.05 1/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50210 1/3/2000 na "Zinc, Total" SM3113 B *non-detect ug/L 100 1/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50478 1/10/2000 na "Alkalinity, Field" SM2320B 26 mg/L 1.2 1/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50477 1/10/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 1/31/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 50478 1/10/2000 na Color SM2120 B modified 24.9 APHA units 2.5 1/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50476 1/10/2000 na "Copper, Total" SM3113 B 4 ug/L 3 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na E. coli SM9223 B 1 CFU/100 mL 0 3/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na Fecal Coliform SM9222 D 1 CFU/100 mL 0 2/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na Fecal Strep SM9230 C 2 CFU/100 mL 0 2/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50479 1/10/2000 na Fluoride EPA 300.0 0.16 mg/L 0.11 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na Heterotrophic Plate Cnt SM9215 B 8 CFU/1.0 mL 0 2/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50476 1/10/2000 na "Iron, Total" SM3113 B 190 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50476 1/10/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50476 1/10/2000 na "Manganese, Total" SM3113 B 3.1 ug/L 1 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50479 1/10/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.13 mg/L N 0.1 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50479 1/10/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/13/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50478 1/10/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.017 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50478 1/10/2000 na "pH, Field" SM4500-H B 7.37 units NA 1/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50477 1/10/2000 na "Phosphorus, Total" SM4500-P B 0.022 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50478 1/10/2000 na "Specific Conductance, Laboratory" SM2510 B 66.7 umhos/cm 10 1/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na "Temperature, Water" SM2500B 8 DEGREES C NA 1/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na Total Coliform SM9223 B 1 CFU/100 mL 0 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50480 1/10/2000 na Total Coliform SM9222 B 1 CFU/100 mL 0 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50475 1/10/2000 na Total Organic Carbon SM5310B 2.97 mg/L 0.83 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50478 1/10/2000 na Turbidity SM2130 B 2.3 NTU 0.05 1/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R40 50306 1/11/2000 na "Alkalinity, Field" SM2320B 25.6 mg/L 1.2 1/12/2000 1M NA FCWQL Horsetooth R40 50311 1/11/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 1/31/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50310 1/11/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50305 1/11/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.6 ug/L 0.6 1/13/2000 1M NA FCWQL Horsetooth R40 50312 1/11/2000 na "Copper, Total" SM3113 B 5.1 ug/L 3 2/4/2000 1M NA FCWQL Horsetooth R40 50308 1/11/2000 na E. coli SM9223 B 3 CFU/100 mL 0 1/13/2000 1M NA FCWQL Horsetooth R40 50310 1/11/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50312 1/11/2000 na "Iron, Total" SM3113 B 173 ug/L 10 2/10/2000 1M NA FCWQL Horsetooth R40 50310 1/11/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50312 1/11/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50312 1/11/2000 na "Manganese, Total" SM3113 B 2.6 ug/L 1 2/4/2000 1M NA FCWQL Horsetooth R40 50307 1/11/2000 na "Nitrate as N, Dissolved" EPA 300.0 *non-detect mg/L N 0.1 1/13/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50307 1/11/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/13/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50306 1/11/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.018 mg/L 0.005 1/27/2000 1M NA FCWQL Horsetooth R40 50310 1/11/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50311 1/11/2000 na "Phosphorus, Total" SM4500-P B 0.033 mg/L 0.005 1/27/2000 1M NA FCWQL Horsetooth R40 50310 1/11/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50308 1/11/2000 na Total Coliform SM9223 B 3 CFU/100 mL 0 1/13/2000 1M NA FCWQL Horsetooth R40 50311 1/11/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.2 mg/L 0.1 1/31/2000 1M NA FCWQL Horsetooth R40 50309 1/11/2000 na Total Organic Carbon SM5310 B 2.78 mg/L 0.83 1/13/2000 1M NA FCWQL Horsetooth R40 50310 1/11/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 1/12/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 50306 1/11/2000 na Turbidity SM2130 B 2.5 NTU 0.05 1/12/2000 1M NA NA BTWF R40 NA 1/11/2000 822 Secchi Depth NA 3.865 m NA NA NA NA FCWQL Horsetooth R42 50398 1/11/2000 na "Alkalinity, Field" SM2320B 25.4 mg/L 1.2 1/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50401 1/11/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.04 mg/L 0.02 1/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50396 1/11/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50403 1/11/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.3 ug/L 0.6 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50400 1/11/2000 na "Copper, Total" SM3113 B *non-detect ug/L 3 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50397 1/11/2000 na E. coli SM9223 B 2 CFU/100 mL 0 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50396 1/11/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50400 1/11/2000 na "Iron, Total" SM3113 B 170 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50396 1/11/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50400 1/11/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50400 1/11/2000 na "Manganese, Total" SM3113 B 2.6 ug/L 1 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50399 1/11/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50399 1/11/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/13/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50398 1/11/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.016 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50396 1/11/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50401 1/11/2000 na "Phosphorus, Total" SM4500-P B 0.021 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50396 1/11/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 1/12/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50397 1/11/2000 na Total Coliform SM9223 B 11 CFU/100 mL 0 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50401 1/11/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.4 mg/L 0.1 1/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50402 1/11/2000 na Total Organic Carbon SM5310 C 2.98 mg/L 0.83 1/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 50398 1/11/2000 na Turbidity SM2130 B 2.4 NTU 0.05 1/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na "Alkalinity, Field" SM2320B 26 mg/L 1.2 1/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50656 1/18/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 1/31/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 50663 1/18/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na Calcium as CaCO3 SM3500-Ca D 20.4 mg/L 2.1 1/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50661 1/18/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 0.9 ug/L 0.6 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na Color SM2120 B modified 22.8 APHA units 2.5 1/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50657 1/18/2000 na "Copper, Total" SM3113 B 4.9 ug/L 3 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50663 1/18/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 4/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50662 1/18/2000 na Fluoride EPA 300.0 0.19 mg/L 0.11 1/19/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na Heterotrophic Plate Cnt SM9215 B 4 CFU/1.0 mL 0 4/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50657 1/18/2000 na "Iron, Total" SM3113 B 151 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50663 1/18/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50657 1/18/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50657 1/18/2000 na "Manganese, Total" SM3113 B 3 ug/L 1 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50662 1/18/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 1/19/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50662 1/18/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.016 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50663 1/18/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na "pH, Field" SM4500-H B 7.36 units NA 1/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50656 1/18/2000 na "Phosphorus, Total" SM4500-P B 0.02 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na "Specific Conductance, Laboratory" SM2510 B 67.8 umhos/cm 10 1/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na "Temperature, Water" SM2500B 8 DEGREES C NA 1/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50663 1/18/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 4/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50660 1/18/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 5/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na Total Dissolved Solids SM2540 C 86 mg/L 10 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50658 1/18/2000 na Total Organic Carbon SM5310B 3.04 mg/L 0.83 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50663 1/18/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 1/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50659 1/18/2000 na Turbidity SM2130 B 2.2 NTU 0.05 1/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na "Alkalinity, Field" SM2320B 26.2 mg/L 1.2 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50807 1/24/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 1/31/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 50804 1/24/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.2 ug/L 0.6 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na Color SM2120 B modified 24.7 APHA units 2.5 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50803 1/24/2000 na "Copper, Total" SM3113 B 12.3 ug/L 3 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na E. coli SM9223 B 0 CFU/100 mL 0 5/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na Fecal Coliform SM9222 D 1 CFU/100 mL 0 5/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 5/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50806 1/24/2000 na Fluoride EPA 300.0 0.16 mg/L 0.11 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na Heterotrophic Plate Cnt SM9215 B 2 CFU/1.0 mL 0 5/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50803 1/24/2000 na "Iron, Total" SM3113 B 161 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50803 1/24/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 2/4/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50803 1/24/2000 na "Manganese, Total" SM3113 B 2.5 ug/L 1 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50806 1/24/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50806 1/24/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 1/25/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.015 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na "pH, Field" SM4500-H B 7.29 units NA 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50807 1/24/2000 na "Phosphorus, Total" SM4500-P B 0.022 mg/L 0.005 1/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na "Silica, Total" SM4500-Si C 4 mg/L 2 1/26/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na "Specific Conductance, Laboratory" SM2510 B 68.7 umhos/cm 10 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 6/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50801 1/24/2000 na Total Coliform SM9222 B 1 CFU/100 mL 0 6/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50802 1/24/2000 na Total Organic Carbon SM5310B 3.19 mg/L 0.83 1/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 50805 1/24/2000 na Turbidity SM2130 B 2.2 NTU 0.05 1/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na "Alkalinity, Field" SM2320B 25.4 mg/L 1.2 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51069 1/31/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 2/3/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 51072 1/31/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1 ug/L 0.6 2/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na Color SM2120 B modified 23 APHA units 2.5 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51070 1/31/2000 na "Copper, Total" SM3113 B 4.1 ug/L 3 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na E. coli SM9223 B 0 CFU/100 mL 0 7/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na Fecal Coliform SM9222 D 1 CFU/100 mL 0 6/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na Fecal Strep SM9230 C 2 CFU/100 mL 0 6/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51074 1/31/2000 na Fluoride EPA 300.0 0.2 mg/L 0.11 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na Heterotrophic Plate Cnt SM9215 B 4 CFU/1.0 mL 0 7/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51070 1/31/2000 na "Iron, Total" SM3113 B 197 ug/L 10 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51070 1/31/2000 na "Manganese, Dissolved" SM3113 B 3 ug/L 1 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51070 1/31/2000 na "Manganese, Total" SM3113 B 5.2 ug/L 1 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51074 1/31/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.16 mg/L N 0.1 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51074 1/31/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/1/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.02 mg/L 0.005 2/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na "pH, Field" SM4500-H B 7.61 units NA 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51069 1/31/2000 na "Phosphorus, Total" SM4500-P B 0.029 mg/L 0.005 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na "Specific Conductance, Laboratory" SM2510 B 55.4 umhos/cm 10 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 1/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 7/18/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51071 1/31/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 7/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51075 1/31/2000 na Total Organic Carbon SM5310B 3 mg/L 0.83 2/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51073 1/31/2000 na Turbidity SM2130 B 2.2 NTU 0.05 2/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R20 51449 2/7/2000 na "Alkalinity, Field" SM2320B 25 mg/L 1.2 2/9/2000 NA A FCWQL Horsetooth R20 51450 2/7/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 2/18/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R20 51451 2/7/2000 na E. coli SM9223 B 0 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R20 51450 2/7/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 2/18/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 51450 2/7/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 2/18/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 51450 2/7/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 2/18/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R20 51450 2/7/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 2/18/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R20 51451 2/7/2000 na Total Coliform SM9223 B 4 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R20 51449 2/7/2000 na Turbidity SM2130 B 2.2 NTU 0.05 2/9/2000 NA NA NA BTWF R20 NA 2/7/2000 NA Secchi Depth NA 3.65 m NA NA NA NA FCWQL Horsetooth R22 51452 2/7/2000 na "Alkalinity, Field" SM2320B 25.2 mg/L 1.2 2/9/2000 NA NA FCWQL Horsetooth R22 51453 2/7/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R22 51454 2/7/2000 na E. coli SM9223 B 0 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R22 51453 2/7/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R22 51453 2/7/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 51453 2/7/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 51453 2/7/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R22 51454 2/7/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R22 51452 2/7/2000 na Turbidity SM2130 B 2.2 NTU 0.05 2/9/2000 NA B FCWQL Horsetooth R40 51458 2/7/2000 na "Alkalinity, Field" SM2320B 25.4 mg/L 1.2 2/9/2000 1M NA FCWQL Horsetooth R40 51461 2/7/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.04 mg/L 0.02 2/24/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51455 2/7/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.2 ug/L 0.6 2/10/2000 1M NA FCWQL Horsetooth R40 51462 2/7/2000 na "Copper, Total" SM3113 B 5.5 ug/L 3 3/10/2000 1M NA FCWQL Horsetooth R40 51457 2/7/2000 na E. coli SM9223 B 0 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51462 2/7/2000 na "Iron, Total" SM3113 B 158 ug/L 10 3/17/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51462 2/7/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51462 2/7/2000 na "Manganese, Total" SM3113 B 2.4 ug/L 1 3/14/2000 1M NA FCWQL Horsetooth R40 51456 2/7/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 2/8/2000 1M NA FCWQL Horsetooth R40 51456 2/7/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51458 2/7/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.012 mg/L 0.005 2/9/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51461 2/7/2000 na "Phosphorus, Total" SM4500-P B 0.015 mg/L 0.005 2/10/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51457 2/7/2000 na Total Coliform SM9223 B 1 CFU/100 mL 0 2/9/2000 1M NA FCWQL Horsetooth R40 51461 2/7/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 *non-detect mg/L 0.1 2/15/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51459 2/7/2000 na Total Organic Carbon SM5310 B 2.9 mg/L 0.83 3/8/2000 1M NA FCWQL Horsetooth R40 51460 2/7/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 2/19/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 51458 2/7/2000 na Turbidity SM2130 B 2.1 NTU 0.05 2/9/2000 1M NA NA BTWF R40 NA 2/7/2000 NA Secchi Depth NA 4.8 m NA NA NA NA FCWQL Horsetooth R41 51369 2/7/2000 na "Alkalinity, Field" SM2320B 24.4 mg/L 1.2 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51371 2/7/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.12 mg/L 0.02 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Calcium, Total" SM3111 D 7.4 mg/L 0.5 2/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51368 2/7/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.1 ug/L 0.6 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51369 2/7/2000 na Color SM2120 B modified 22 APHA units 2.5 2/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Copper, Total" SM3113 B 4.7 ug/L 3 3/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na E. coli SM9223 B 0 CFU/100 mL 0 8/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na Fecal Coliform SM9222 D 2 CFU/100 mL 0 8/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 8/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51370 2/7/2000 na Fluoride EPA 300.0 0.12 mg/L 0.11 2/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na Heterotrophic Plate Cnt SM9215 B 6 CFU/1.0 mL 0 8/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Iron, Total" SM3113 B 131 ug/L 10 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Lead, Total" SM3113 B *non-detect ug/L 1 3/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Magnesium, Total" SM3111 B 1.3 mg/L 0.2 2/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Manganese, Total" SM3113 B 4.1 ug/L 1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51370 2/7/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 2/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51370 2/7/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/8/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51369 2/7/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.011 mg/L 0.005 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51369 2/7/2000 na "pH, Field" SM4500-H B 7.8 units NA 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51371 2/7/2000 na "Phosphorus, Total" SM4500-P B 0.02 mg/L 0.005 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Potassium, Total" SM3111 B 0.6 mg/L 0.2 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51367 2/7/2000 na "Sodium, Total" SM3111 B 2.4 mg/L 0.4 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51369 2/7/2000 na "Specific Conductance, Laboratory" SM2510 B 55.2 umhos/cm 10 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 8/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51365 2/7/2000 na Total Coliform SM9222 B 2 CFU/100 mL 0 9/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51371 2/7/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 *non-detect mg/L 0.1 2/15/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51366 2/7/2000 na Total Organic Carbon SM5310B 3.18 mg/L 0.83 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51369 2/7/2000 na Turbidity SM2130 B 2.1 NTU 0.05 2/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51552 2/7/2000 na "Alkalinity, Field" SM2320B 25.8 mg/L 1.2 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51549 2/7/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.05 mg/L 0.02 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51553 2/7/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51548 2/7/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1 ug/L 0.6 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51550 2/7/2000 na "Copper, Total" SM3113 B 3 ug/L 3 3/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51547 2/7/2000 na E. coli SM9223 B 0 CFU/100 mL 0 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51553 2/7/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51550 2/7/2000 na "Iron, Total" SM3113 B 158 ug/L 10 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51553 2/7/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51550 2/7/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51550 2/7/2000 na "Manganese, Total" SM3113 B 2.1 ug/L 1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51551 2/7/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.15 mg/L N 0.1 2/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51551 2/7/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/8/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51552 2/7/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.01 mg/L 0.005 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51553 2/7/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51549 2/7/2000 na "Phosphorus, Total" SM4500-P B 0.017 mg/L 0.005 2/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51553 2/7/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 2/19/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51547 2/7/2000 na Total Coliform SM9223 B 1 CFU/100 mL 0 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51549 2/7/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.1 mg/L 0.1 2/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51546 2/7/2000 na Total Organic Carbon SM5310 C 3.29 mg/L 0.83 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 51552 2/7/2000 na Turbidity SM2130 B 2.2 NTU 0.05 2/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na "Alkalinity, Field" SM2320B 25.6 mg/L 1.2 2/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51880 2/14/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.04 mg/L 0.02 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51877 2/14/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.4 ug/L 0.6 3/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na Color SM2120 B modified 21.7 APHA units 2.5 2/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51876 2/14/2000 na "Copper, Total" SM3113 B 4.6 ug/L 3 3/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na E. coli SM9223 B 0 CFU/100 mL 0 10/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 9/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 9/19/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51879 2/14/2000 na Fluoride EPA 300.0 0.14 mg/L 0.11 2/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na Heterotrophic Plate Cnt SM9215 B 8 CFU/1.0 mL 0 10/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51876 2/14/2000 na "Iron, Total" SM3113 B 203 ug/L 10 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51876 2/14/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51876 2/14/2000 na "Manganese, Total" SM3113 B 3.3 ug/L 1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51879 2/14/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 2/15/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51879 2/14/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/15/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.007 mg/L 0.005 2/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na "pH, Field" SM4500-H B 7.48 units NA 2/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51880 2/14/2000 na "Phosphorus, Total" SM4500-P B 0.014 mg/L 0.005 2/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na "Specific Conductance, Laboratory" SM2510 B 66.9 umhos/cm 10 2/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 2/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 10/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51874 2/14/2000 na Total Coliform SM9222 B 1 CFU/100 mL 0 10/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51875 2/14/2000 na Total Organic Carbon SM5310B 2.75 mg/L 0.83 3/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 51878 2/14/2000 na Turbidity SM2130 B 2.1 NTU 0.05 2/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na "Alkalinity, Field" SM2320B 26 mg/L 1.2 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52089 2/22/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.03 mg/L 0.02 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52095 2/22/2000 na "Chloride, Dissolved" EPA 300.0 1.6 mg/L 1 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52094 2/22/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.4 ug/L 0.6 3/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na Color SM2120 B modified 24.5 APHA units 2.5 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52096 2/22/2000 na "Copper, Total" SM3113 B 5.2 ug/L 3 3/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na E. coli SM9223 B 0 CFU/100 mL 0 11/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 10/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 11/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52095 2/22/2000 na Fluoride EPA 300.0 0.15 mg/L 0.11 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52096 2/22/2000 na "Iron, Total" SM3113 B 196 ug/L 10 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52096 2/22/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52096 2/22/2000 na "Manganese, Total" SM3113 B 3.1 ug/L 1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52095 2/22/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.13 mg/L N 0.1 2/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52095 2/22/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/24/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.017 mg/L 0.005 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na "pH, Field" SM4500-H B 7.71 units NA 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52089 2/22/2000 na "Phosphorus, Total" SM4500-P B 0.022 mg/L 0.005 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na "Silica, Total" SM4500-Si C 4.3 mg/L 2 3/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na "Specific Conductance, Laboratory" SM2510 B 68 umhos/cm 10 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52095 2/22/2000 na "Sulfate, Dissolved" EPA 300.0 *non-detect mg/L 5 2/24/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na "Temperature, Water" SM2500B 6.5 DEGREES C NA 2/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 11/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52093 2/22/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 12/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na Total Dissolved Solids SM2540 C 92 mg/L 10 2/25/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52090 2/22/2000 na Total Organic Carbon SM5310B 2.75 mg/L 0.83 3/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52091 2/22/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 3/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52092 2/22/2000 na Turbidity SM2130 B 2.2 NTU 0.05 2/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na "Alkalinity, Field" SM2320B 25.8 mg/L 1.2 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52254 2/28/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.05 mg/L 0.02 3/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52256 2/28/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.6 ug/L 0.6 3/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na Color SM2120 B modified 23.2 APHA units 2.5 2/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52259 2/28/2000 na "Copper, Total" SM3113 B 6.3 ug/L 3 3/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na E. coli SM9223 B 0 CFU/100 mL 0 1/3/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 12/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 12/19/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52258 2/28/2000 na Fluoride EPA 300.0 0.17 mg/L 0.11 3/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na Heterotrophic Plate Cnt SM9215 B 4 CFU/1.0 mL 0 12/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52259 2/28/2000 na "Iron, Total" SM3113 B 182 ug/L 10 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52259 2/28/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52259 2/28/2000 na "Manganese, Total" SM3113 B 3.1 ug/L 1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52258 2/28/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.15 mg/L N 0.1 3/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52258 2/28/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/1/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.014 mg/L 0.005 3/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na "pH, Field" SM4500-H B 7.77 units NA 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52254 2/28/2000 na "Phosphorus, Total" SM4500-P B 0.014 mg/L 0.005 3/1/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na "Specific Conductance, Laboratory" SM2510 B 62.8 umhos/cm 10 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na "Temperature, Water" SM2500B 6.5 DEGREES C NA 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 1/9/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52253 2/28/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 1/17/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52255 2/28/2000 na Total Organic Carbon SM5310B 2.81 mg/L 0.83 3/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52257 2/28/2000 na Turbidity SM2130 B 2.7 NTU 0.05 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R20 52373 3/6/2000 na "Alkalinity, Field" SM2320B 24.2 mg/L 1.2 3/8/2000 NA NA FCWQL Horsetooth R20 52374 3/6/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R20 52375 3/6/2000 na E. coli SM9223 B 1 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R20 52374 3/6/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R20 52374 3/6/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 52374 3/6/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 52374 3/6/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R20 52375 3/6/2000 na Total Coliform SM9223 B 7 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R20 52373 3/6/2000 na Turbidity SM2130 B 2.3 NTU 0.05 3/8/2000 NA B NA BTWF R20 NA 3/6/2000 NA Secchi Depth NA 3.13 m NA NA NA NA FCWQL Horsetooth R22 52376 3/6/2000 na "Alkalinity, Field" SM2320B 24.6 mg/L 1.2 3/8/2000 NA NA FCWQL Horsetooth R22 52377 3/6/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 52378 3/6/2000 na E. coli SM9223 B 0 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R22 52377 3/6/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 52377 3/6/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R22 52377 3/6/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R22 52377 3/6/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 52378 3/6/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R22 52376 3/6/2000 na Turbidity SM2130 B 2.4 NTU 0.05 3/8/2000 NA NA FCWQL Horsetooth R40 52382 3/6/2000 na "Alkalinity, Field" SM2320B 25.4 mg/L 1.2 3/8/2000 1M NA FCWQL Horsetooth R40 52385 3/6/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52384 3/6/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52379 3/6/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2 ug/L 0.6 3/17/2000 1M NA FCWQL Horsetooth R40 52386 3/6/2000 na "Copper, Total" SM3113 B 3.6 ug/L 3 3/30/2000 1M NA FCWQL Horsetooth R40 52381 3/6/2000 na E. coli SM9223 B 0 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R40 52384 3/6/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52386 3/6/2000 na "Iron, Total" SM3113 B 165 ug/L 10 4/3/2000 1M NA FCWQL Horsetooth R40 52384 3/6/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52386 3/6/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52386 3/6/2000 na "Manganese, Total" SM3113 B 2 ug/L 1 3/28/2000 1M NA FCWQL Horsetooth R40 52380 3/6/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.15 mg/L N 0.1 3/7/2000 1M NA FCWQL Horsetooth R40 52380 3/6/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/7/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52382 3/6/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.018 mg/L 0.005 3/8/2000 1M NA FCWQL Horsetooth R40 52384 3/6/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52385 3/6/2000 na "Phosphorus, Total" SM4500-P B 0.021 mg/L 0.005 3/8/2000 1M NA FCWQL Horsetooth R40 52384 3/6/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52381 3/6/2000 na Total Coliform SM9223 B 2 CFU/100 mL 0 3/8/2000 1M NA FCWQL Horsetooth R40 52385 3/6/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.3 mg/L 0.1 3/23/2000 1M NA FCWQL Horsetooth R40 52383 3/6/2000 na Total Organic Carbon SM5310 B 2.99 mg/L 0.83 3/9/2000 1M NA FCWQL Horsetooth R40 52384 3/6/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 3/8/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 52382 3/6/2000 na Turbidity SM2130 B 2.4 NTU 0.05 3/8/2000 1M NA NA BTWF R40 NA 3/6/2000 NA Secchi Depth NA 4.52 m NA NA NA NA FCWQL Horsetooth R41 52574 3/6/2000 na "Alkalinity, Field" SM2320B 25.2 mg/L 1.2 3/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52576 3/6/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 52572 3/6/2000 na "Calcium, Total" SM3111 D 8.9 mg/L 0.5 5/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52573 3/6/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.7 ug/L 0.6 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52574 3/6/2000 na Color SM2120 B modified 20.4 APHA units 2.5 3/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Copper, Total" SM3113 B 4.1 ug/L 3 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na E. coli SM9223 B 0 CFU/100 mL 0 2/13/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na Fecal Coliform SM9222 D 1 CFU/100 mL 0 1/23/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 1/30/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52575 3/6/2000 na Fluoride EPA 300.0 0.15 mg/L 0.11 3/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na Heterotrophic Plate Cnt SM9215 B 20 CFU/1.0 mL 0 2/6/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Iron, Total" SM3113 B 167 ug/L 10 3/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Lead, Total" SM3113 B *non-detect ug/L 1 3/20/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Magnesium, Total" SM3111 B 1.5 mg/L 0.2 4/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Manganese, Total" SM3113 B 2.2 ug/L 1 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52575 3/6/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.14 mg/L N 0.1 3/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52575 3/6/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/7/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52574 3/6/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.013 mg/L 0.005 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52574 3/6/2000 na "pH, Field" SM4500-H B 7.42 units NA 3/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52576 3/6/2000 na "Phosphorus, Total" SM4500-P B 0.018 mg/L 0.005 3/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Potassium, Total" SM3111 B 0.6 mg/L 0.2 5/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52572 3/6/2000 na "Sodium, Total" SM3111 B 2.4 mg/L 0.4 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52574 3/6/2000 na "Specific Conductance, Laboratory" SM2510 B 67.5 umhos/cm 10 3/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na "Temperature, Water" SM2500B 8.5 DEGREES C NA 3/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 2/21/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52570 3/6/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 3/6/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52576 3/6/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.4 mg/L 0.1 3/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52571 3/6/2000 na Total Organic Carbon SM5310B 2.9 mg/L 0.83 3/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52574 3/6/2000 na Turbidity SM2130 B 2.2 NTU 0.05 3/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52476 3/6/2000 na "Alkalinity, Field" SM2320B 25.6 mg/L 1.2 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52473 3/6/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/8/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R42 52477 3/6/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/9/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52472 3/6/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 1.8 ug/L 0.6 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52474 3/6/2000 na "Copper, Total" SM3113 B 3.8 ug/L 3 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52471 3/6/2000 na E. coli SM9223 B 0 CFU/100 mL 0 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52477 3/6/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/9/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52474 3/6/2000 na "Iron, Total" SM3113 B 201 ug/L 10 3/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52477 3/6/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/9/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52474 3/6/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52474 3/6/2000 na "Manganese, Total" SM3113 B 1.7 ug/L 1 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52475 3/6/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.15 mg/L N 0.1 3/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52475 3/6/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/7/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52476 3/6/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.028 mg/L 0.005 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52477 3/6/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/9/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52473 3/6/2000 na "Phosphorus, Total" SM4500-P B 0.019 mg/L 0.005 3/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52477 3/6/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/9/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52471 3/6/2000 na Total Coliform SM9223 B 1 CFU/100 mL 0 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52473 3/6/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.3 mg/L 0.1 3/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52470 3/6/2000 na Total Organic Carbon SM5310 C 3.04 mg/L 0.83 3/9/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 52476 3/6/2000 na Turbidity SM2130 B 2.3 NTU 0.05 3/8/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na "Alkalinity, Field" SM2320B 26.2 mg/L 1.2 3/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52740 3/13/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/22/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 52737 3/13/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.2 ug/L 0.6 3/17/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na Color SM2120 B modified 20.8 APHA units 2.5 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52736 3/13/2000 na "Copper, Total" SM3113 B 8.1 ug/L 3 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/10/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 3/20/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 3/28/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52739 3/13/2000 na Fluoride EPA 300.0 0.17 mg/L 0.11 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na Heterotrophic Plate Cnt SM9215 B 3 CFU/1.0 mL 0 4/3/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52736 3/13/2000 na "Iron, Total" SM3113 B 184 ug/L 10 3/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52736 3/13/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52736 3/13/2000 na "Manganese, Total" SM3113 B 1.9 ug/L 1 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52739 3/13/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.13 mg/L N 0.1 3/14/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52739 3/13/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/14/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.018 mg/L 0.005 3/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na "pH, Field" SM4500-H B 7.65 units NA 3/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52740 3/13/2000 na "Phosphorus, Total" SM4500-P B 0.019 mg/L 0.005 3/16/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na "Specific Conductance, Laboratory" SM2510 B 67.7 umhos/cm 10 3/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na "Temperature, Water" SM2500B 8 DEGREES C NA 3/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 4/17/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52734 3/13/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 5/1/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52735 3/13/2000 na Total Organic Carbon SM5310B 2.51 mg/L 0.83 3/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 52738 3/13/2000 na Turbidity SM2130 B 2.4 NTU 0.05 3/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na "Alkalinity, Field" SM2320B 25.4 mg/L 1.2 3/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53088 3/20/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/22/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 53086 3/20/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na Calcium as CaCO3 SM3500-Ca D 23.4 mg/L 2.1 3/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53092 3/20/2000 na "Chloride, Dissolved" EPA 300.0 1.4 mg/L 1 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53091 3/20/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 3.1 ug/L 0.6 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na Color SM2120 B modified 19.7 APHA units 2.5 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53087 3/20/2000 na "Copper, Total" SM3113 B 5.5 ug/L 3 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na E. coli SM9223 B 0 CFU/100 mL 0 5/30/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53086 3/20/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 5/8/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 5/15/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53092 3/20/2000 na Fluoride EPA 300.0 0.16 mg/L 0.11 3/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na Heterotrophic Plate Cnt SM9215 B 7 CFU/1.0 mL 0 5/22/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53087 3/20/2000 na "Iron, Total" SM3113 B 245 ug/L 10 3/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53086 3/20/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53087 3/20/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53087 3/20/2000 na "Manganese, Total" SM3113 B 1.7 ug/L 1 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53092 3/20/2000 na "Nitrate as N, Dissolved" EPA 300.0 *non-detect mg/L N 0.1 3/21/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53092 3/20/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 3/21/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.013 mg/L 0.005 3/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53086 3/20/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na "pH, Field" SM4500-H B 7.64 units NA 3/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53088 3/20/2000 na "Phosphorus, Total" SM4500-P B 0.016 mg/L 0.005 3/23/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na "Silica, Total" SM4500-Si C 4 mg/L 2 3/24/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na "Specific Conductance, Laboratory" SM2510 B 68.5 umhos/cm 10 3/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53092 3/20/2000 na "Sulfate, Dissolved" EPA 300.0 *non-detect mg/L 5 3/21/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na "Temperature, Water" SM2500B 6 DEGREES C NA 3/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53086 3/20/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 6/5/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53090 3/20/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 6/12/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na Total Dissolved Solids SM2540 C 42 mg/L 10 3/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53093 3/20/2000 na Total Organic Carbon SM5310B 2.87 mg/L 0.83 3/22/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53086 3/20/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 3/22/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53089 3/20/2000 na Turbidity SM2130 B 2.3 NTU 0.05 3/20/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na "Alkalinity, Field" SM2320B 25 mg/L 1.2 3/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53282 3/27/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C *non-detect mg/L 0.02 3/30/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R41 53284 3/27/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 3.4 ug/L 0.6 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na Color SM2120 B modified 19 APHA units 2.5 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53281 3/27/2000 na "Copper, Total" SM3113 B 4.5 ug/L 3 3/30/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na E. coli SM9223 B 0 CFU/100 mL 0 7/10/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 6/19/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na Fecal Strep SM9230 C 1 CFU/100 mL 0 6/26/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53286 3/27/2000 na Fluoride EPA 300.0 0.14 mg/L 0.11 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na Heterotrophic Plate Cnt SM9215 B 6 CFU/1.0 mL 0 7/3/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53281 3/27/2000 na "Iron, Total" SM3113 B 198 ug/L 10 3/31/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53281 3/27/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 3/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53281 3/27/2000 na "Manganese, Total" SM3113 B 2.2 ug/L 1 3/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53286 3/27/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.12 mg/L N 0.1 2/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53286 3/27/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 2/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.013 mg/L 0.005 3/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na "pH, Field" SM4500-H B 7.62 units NA 3/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53282 3/27/2000 na "Phosphorus, Total" SM4500-P B 0.015 mg/L 0.005 3/29/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na "Specific Conductance, Laboratory" SM2510 B 67.7 umhos/cm 10 3/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na "Temperature, Water" SM2500B 8.5 DEGREES C NA 3/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 7/17/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53283 3/27/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 7/24/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53287 3/27/2000 na Total Organic Carbon SM5310B 2.73 mg/L 0.83 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53285 3/27/2000 na Turbidity SM2130 B 2.2 NTU 0.05 3/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R20 53431 4/3/2000 na "Alkalinity, Field" SM2320B 26 mg/L 1.2 4/5/2000 NA NA FCWQL Horsetooth R20 53432 4/3/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 53433 4/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R20 53432 4/3/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 53432 4/3/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 53432 4/3/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 53432 4/3/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R20 53433 4/3/2000 na Total Coliform SM9223 B 6 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R20 53431 4/3/2000 na Turbidity SM2130 B 2.4 NTU 0.05 4/5/2000 NA NA NA BTWF R20 NA 4/3/2000 NA Secchi Depth NA 3.12 m NA NA NA NA FCWQL Horsetooth R22 53434 4/3/2000 na "Alkalinity, Field" SM2320B 26.2 mg/L 1.2 4/5/2000 NA A FCWQL Horsetooth R22 53435 4/3/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R22 53436 4/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R22 53435 4/3/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 53435 4/3/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA Parameter less than reporting level. FCWQL Horsetooth R22 53435 4/3/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA A Parameter less than reporting level. FCWQL Horsetooth R22 53435 4/3/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA B Parameter less than reporting level. FCWQL Horsetooth R22 53436 4/3/2000 na Total Coliform SM9223 B 1 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R22 53434 4/3/2000 na Turbidity SM2130 B 2.7 NTU 0.05 4/5/2000 NA NA FCWQL Horsetooth R40 53440 4/3/2000 na "Alkalinity, Field" SM2320B 26 mg/L 1.2 4/5/2000 1M NA FCWQL Horsetooth R40 53443 4/3/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.07 mg/L 0.02 4/6/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53437 4/3/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.9 ug/L 0.6 4/7/2000 1M NA FCWQL Horsetooth R40 53444 4/3/2000 na "Copper, Total" SM3113 B 3.3 ug/L 3 5/4/2000 1M NA FCWQL Horsetooth R40 53439 4/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53444 4/3/2000 na "Iron, Total" SM3113 B 152 ug/L 10 4/27/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53444 4/3/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 4/28/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53444 4/3/2000 na "Manganese, Total" SM3113 B 1.7 ug/L 1 4/28/2000 1M NA FCWQL Horsetooth R40 53438 4/3/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.12 mg/L N 0.1 4/6/2000 1M NA FCWQL Horsetooth R40 53438 4/3/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 4/6/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53440 4/3/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.013 mg/L 0.005 4/5/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53443 4/3/2000 na "Phosphorus, Total" SM4500-P B 0.018 mg/L 0.005 4/5/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53439 4/3/2000 na Total Coliform SM9223 B 3 CFU/100 mL 0 4/5/2000 1M NA FCWQL Horsetooth R40 53443 4/3/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.2 mg/L 0.1 4/27/2000 1M NA FCWQL Horsetooth R40 53441 4/3/2000 na Total Organic Carbon SM5310 B 2.83 mg/L 0.83 4/5/2000 1M NA FCWQL Horsetooth R40 53442 4/3/2000 na "Xylene, Total" EPA 502.2 *non-detect ug/L 0.5 4/11/2000 1M NA Parameter less than reporting level. FCWQL Horsetooth R40 53440 4/3/2000 na Turbidity SM2130 B 2.2 NTU 0.05 4/5/2000 1M NA NA BTWF R40 NA 4/3/2000 NA Secchi Depth NA 3.45 m NA NA NA NA FCWQL Horsetooth R41 53634 4/3/2000 na "Alkalinity, Field" SM2320B 25 mg/L 1.2 4/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53631 4/3/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.03 mg/L 0.02 4/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Calcium, Total" SM3111 D 8.9 mg/L 0.5 5/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53633 4/3/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.8 ug/L 0.6 4/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Copper, Total" SM3113 B 5.9 ug/L 3 5/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 8/21/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 7/31/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 8/7/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53635 4/3/2000 na Fluoride EPA 300.0 0.15 mg/L 0.11 4/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na Heterotrophic Plate Cnt SM9215 B 0 CFU/1.0 mL 0 8/14/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Iron, Total" SM3113 B 117 ug/L 10 4/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Lead, Total" SM3113 B *non-detect ug/L 1 4/25/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Magnesium, Total" SM3111 B 1.6 mg/L 0.2 9/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 5/2/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Manganese, Total" SM3113 B 2.1 ug/L 1 5/2/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53635 4/3/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.11 mg/L N 0.1 4/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53635 4/3/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 4/6/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53634 4/3/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.014 mg/L 0.005 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53634 4/3/2000 na "pH, Field" SM4500-H B 7.48 units NA 4/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53631 4/3/2000 na "Phosphorus, Total" SM4500-P B 0.013 mg/L 0.005 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Potassium, Total" SM3111 B 0.6 mg/L 0.2 5/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53636 4/3/2000 na "Sodium, Total" SM3111 B 2.4 mg/L 0.4 4/13/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53634 4/3/2000 na "Specific Conductance, Laboratory" SM2510 B 68.3 umhos/cm 10 4/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na "Temperature, Water" SM2500B 8 DEGREES C NA 4/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 8/28/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53632 4/3/2000 na Total Coliform SM9222 B 0 CFU/100 mL 0 9/5/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53631 4/3/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.1 mg/L 0.1 4/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53630 4/3/2000 na Total Organic Carbon SM5310B 2.86 mg/L 0.83 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53634 4/3/2000 na Turbidity SM2130 B 2.1 NTU 0.05 4/3/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53534 4/3/2000 na "Alkalinity, Field" SM2320B 26.4 mg/L 1.2 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53531 4/3/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.04 mg/L 0.02 4/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53535 4/3/2000 na Benzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53530 4/3/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.3 ug/L 0.6 4/7/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53532 4/3/2000 na "Copper, Total" SM3113 B 4 ug/L 3 5/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53529 4/3/2000 na E. coli SM9223 B 0 CFU/100 mL 0 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53535 4/3/2000 na Ethylbenzene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53532 4/3/2000 na "Iron, Total" SM3113 B 186 ug/L 10 4/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53535 4/3/2000 na m+p Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53532 4/3/2000 na "Manganese, Dissolved" SM3113 B *non-detect ug/L 1 4/28/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53532 4/3/2000 na "Manganese, Total" SM3113 B 1.5 ug/L 1 4/28/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53533 4/3/2000 na "Nitrate as N, Dissolved" EPA 300.0 0.13 mg/L N 0.1 4/6/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53533 4/3/2000 na "Nitrite as N, Dissolved" EPA 300.0 *non-detect mg/L 0.1 4/6/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53534 4/3/2000 na "Orthophosphate, Dissolved" SM4500-P B 0.017 mg/L 0.005 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53535 4/3/2000 na o-Xylene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53531 4/3/2000 na "Phosphorus, Total" SM4500-P B 0.02 mg/L 0.005 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53535 4/3/2000 na Toluene EPA 502.2 *non-detect ug/L 0.4 4/11/2000 NA NA "Parameter less than reporting level. Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53529 4/3/2000 na Total Coliform SM9223 B 0 CFU/100 mL 0 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53531 4/3/2000 na "Ammonia + Organic Nitrogen, Total" EPA 351.2 0.1 mg/L 0.1 4/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53528 4/3/2000 na Total Organic Carbon SM5310 C 3.92 mg/L 0.83 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R42 53534 4/3/2000 na Turbidity SM2130 B 2.3 NTU 0.05 4/5/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53823 4/10/2000 na "Alkalinity, Field" SM2320B 26.2 mg/L 1.2 4/10/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53820 4/10/2000 na "Ammonia, Dissolved" Lachat 10-107-06-2C 0.03 mg/L 0.02 4/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53822 4/10/2000 na Chlorophyl a "Lake Tahoe, Fluorometric" 2.3 ug/L 0.6 4/21/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53823 4/10/2000 na Color SM2120 B modified 22.4 APHA units 2.5 4/11/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53819 4/10/2000 na "Copper, Total" SM3113 B 5.4 ug/L 3 5/4/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53821 4/10/2000 na E. coli SM9223 B 0 CFU/100 mL 0 10/2/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53821 4/10/2000 na Fecal Coliform SM9222 D 0 CFU/100 mL 0 9/11/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53821 4/10/2000 na Fecal Strep SM9230 C 0 CFU/100 mL 0 9/18/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53824 4/10/2000 na Fluoride EPA 300.0 0.19 mg/L 0.11 4/12/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53821 4/10/2000 na Heterotrophic Plate Cnt SM9215 B 3 CFU/1.0 mL 0 9/25/2001 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53819 4/10/2000 na "Iron, Total" SM3113 B 135 ug/L 10 4/27/2000 NA NA "Samples have the potential to be ""stale"": analyst cannot tell if flow thru pipe is sufficient to keep water flowing." FCWQL Horsetooth R41 53819 4/10/